Content | Device to exercise the respiration through inspiration.
The respiratory-exerciser Respiprogram helps the patient to recover the normal respiration after a chest or abdominal surgery.
The device is composed of: 1 base, 3 small balls different in dimension and colours, 1 transparent central part divided into 3 rooms, 1 tube and mouthpiece.
Each unit packed in single box.
Made in Italy.
Multilanguage box and instruction: GB, FR, IT, ES, PT, DE, GR, Arab. | Riester Metpak® Infusion cuff - 3000 cc - latex free
Pressure cuff for infusion with high quality chromeplated gauge Ø 49 mm up to 300 mmHg.
Sturdy blue cotton cuff washable at 60°
Made in Germany. | Air conduction phone - spare for Cod. 33610, 33612. | SP-10 POCKET SPIROMETER WITH BLUETOOTH
Pocket, portable spirometer with large TFT screen to clearly display both numbers and flow charts.
Synchronously measure FVC, PEF, FEV1, FEV1%, FEF25, FEF2575, FEF75.
Support diagnosis evidence by volume and fl ow rate chart display. Built-in predicted values.
Built-in lithium rechargeable battery and battery power display.
Supplied with USB cable for PC connection, battery charger and software to calculate data and analyse trend. | PA5 is a paediatric portable audiometer with air conduction, free-field and visual stimulation capabilities. By means of a headphone it can be also used as a regular screening audiometer for adults. PA5 unique features are primarily meant to help doctors in evaluating the auditory behaviour in neonates and infants till 24 months of age by means of specific tests:
Auropalpebral Reflex (APR) test
APR test is a startle reflex of the eyelid elicited by relatively strong sounds that can be performed on neonates from the day of birth. It is not based on co-operation with the newborn child.
Conditioned Orientation Response (COR) test
COR test is based on the phenomenon called “Orientation Reflex” which is a natural reflex movement elicited by sound or visual stimulation. If the visual stimulation elicits a reflex which is conditioned by a tone, the child will look towards the visual stimulation as soon as the tone is heard. If the conditioning is effective the child will look in the direction of the sound source even before the visual stimulation is presented.
Visual Reinforcement Audiometry (VRA) test
VRA test is an extension and modification of COR, where the cooperation with the child is less important. Not only the sound localisation orientation reflex are accepted, but also four other reactions: reflex reactions (body and face), search reactions, orientation reactions and spontaneous reactions.
Reflex audiometry and maturation of auditory response tests
Different stimuli are presented in terms of intensity, frequency, duration, direction of sound in order to elicit proper reactions like waking-up, crying, astonishment, direct sound localization.
Supplied with GB manual and quick guide (GB, US, DE, FR, SE, IT, PT, DK, FI, ES, GR, CZ, PL, NL, NO, EE, HU, SL). | SPIROLAB® spirometer with 7” touchscreen and SpO2
Fast, simple, durable diagnostic spirometer.
Features
- FVC, VC, MVV, PRE/POST Bronchodilator comparison with a wide range of selectable parameters
- long life rechargeable battery
- colour Touchscreen 7“ display
- direct connection to external USB Printer PostScript
- 10,000 Spirometry tests or 500 hours of oximetry recording
- wireless Real Time test on PC via Bluetooth®
- fast and silent built-in B/W printer with customizable printout format
- selectable internal software languages: GB, FR, IT, ES, DE, PT
Oximetry option
Available adult and pediatric reusable finger probe.
Fast and user friendly
Each function can be activated by a simple touch.
FlowMIR® disposable turbine
- complies with ATS/ERS standard
Totally disposable (mouthpiece, turbine) guarantees 100% hygiene, no cross contamination.
No calibration required.
Suitable for children
Patented pediatric incentive directly on the screen.
No need of adaptor.
Made in Italy.
WinspiroPRO®
High perfomances PC software for spirometry and oximetry with free update.
Multilingual software: GB, FR, IT, ES, DE, PT, PL, NL, LV, SE, CZ, RU, TR, JP, CN.
Dimensions: 220x210x51 mm (8,66x8,26x2“)
Weight: 1450 g (3,1lb) (battery pack included) |
Additional information |
Weight |
0.17 kg |
Dimensions |
15 × 15 × 8.2 cm |
Unit |
1 pc.
|
|
Weight |
0.65 kg |
Dimensions |
31 × 15 × 2 cm |
Unit |
1 pc.
|
|
Weight |
0.5 kg |
Dimensions |
24 × 16.5 × 9 cm |
Unit |
1 pc.
|
|
Weight |
0.7 kg |
Dimensions |
24 × 19 × 8 cm |
Technical Specification |
• Max volume: 10 L • Flow range: 1 L/sec – 16 L/sec • Volume accuracy: ±3% or 50 ml whichever is greater • Flow accuracy: ± 10% or 0.3 L/sec whichever is greater • Parameters: FVC, FEF25, FEF2575, FEF75 • Made in PRC • CE 92/42 – EMC group I class B – protection type BF, FEV1, FEV1%, PEF
|
Standard Accessories |
• Internal lithium battery • USB cable • PC software (english language) • Manual: GB, ES., FR, IT
|
Unit |
1 pc.
|
|
Weight |
1.1 kg |
Dimensions |
33.5 × 15 × 15 cm |
Technical Specification |
• Frequencies: 500, 1000, 2000, 3000, 4000 Hz. • Stimuli: Warble tone, for Warble Tone and WN – 10/20–70 dB for NB • Distance 16 cm: increases intensity by 10 dB. • Weight: 360 g • Size 25 x 7 x h 5 cm • Power supply: 3 AA batteries (included), NB and WN • Intensities: Distance 50 cm: – 20/30-80 dB HL in 10 dB steps
|
Unit |
1 pc.
|
|
Weight |
5.8 kg |
Dimensions |
48 × 48 × 18 cm |
Technical Specification |
• Spirometry Power supply: Rechargeable battery, 7 (32/64 bit), 8 and 8.1 (32/64 bit), 800×480 resolution Mouthpieces: Ø 30 mm (1.18 inch) Electrical protection: Class II Norms: Electrical safety standard EN 60601-1, Average), Bluetooth® 2.1 Display: 7” colour touch screen LCD, Electromagnetic compatibility EN 60601-1-2 • Spirometry parameters FVC, ERV, Extrapolated Volume, FEF25, FEF25-75, FEF50, FEF50/FIF50, FEF75, FEF75-85, FET, FEV0.5, FEV0.5/FVC, FEV0.75, FEV0.75/FVC, FEV1, FEV1/ FEV6, FEV1/FEV0.5, FEV1/FVC, FEV1/PEF, FEV1/VC, FEV2, FEV2/FVC, FEV3, FEV3/FVC, FEV6, FIF25, FIF50, FIF75, FIV1, FIV1/FIVC, FIVC, IC, IRV, IVC, Lung Age, Max, MVV (calculated). • WINSPIRO PRO® REQUIREMENTS Windows 2000, MVV (measured), PEF, PIF, Rf, T120 (Tachycardia duration with Pulse Rate >120 BPM), T40 (Bradycardia duration with Pulse Rate <40 BPM), T89% (SpO2 time =88%), T90% (SpO2 time =89%), te, tE/tTOT, Test duration, ti, Time to PEF, Total SpO2 Events, VC, VE, Vista (32/64 bit), VT, VT/ti, XP
|
Standard Accessories |
Battery charger Software WinspiroPRO® 1 roll thermal paper USB port and cable Reusable turbine SpO2 adult sensor Nose clip CD manual: GB, DE, ES, FR, IT, PT Carrying case
|
Unit |
1 pc.
|
|