Content | AMBU® AURAONCE™ DISPOSABLE LARYNGEAL MASKS
• Laryngeal Mask N 2
• Colour: pink
• Patient weight: 10-20 kg
• Maximum cuff inflation volume: 10 ml
AuraOnce has a special curve that carefully replicates natural human anatomy.
Molded directly into the tube, the unique shape makes correct insertion easy without abrading the upper airway.
AuraOnce's curve also ensures that the patient's head remains in a natural supine position when the mask is in use without extra stress on the upper jaw. Moreover, Auraonce is specially designed to give the airway tube the flexibility needed to adapt to individual anatomical variances and wide range of
head positions.
AuraOnce has a D-shaped airway tube to give a firm and ergonomical grip during insertion. In short, positioning is fast and accurate, with least possible internal pressure.
The airway tube is flexible at the cuff and rigid at the connector for easy, atraumatic insertion and removal.
Cuff and airway tube moulded as single unit with built-in, anatomically correct curve.
Smooth sides without ridges or fins that can scratch delicate tissue.
Reinforced tip will not bend during insertion so positioning is always correct.
Ultra thin pilot balloon with universal check valve provides precise tactile indication of degree of inflation.
Reinforced tip will not bend during insertion so positioning is always correct.
Universal 15 mm connector (ISO). | AMBU® AURAGAIN™ DISPOSABLE LARYNGEAL MASKS
• Laryngeal Mask N 3
• Patient weight: 30-50 kg
• Max mask ET-Tubes Max (Ø of endotracheal tube): 6.5 mm
• Gastric-Tube max (FR): 16 FR
• Maximum cuff inflation volume: 20 ml
The AuraGain satisfies 3 fundamental airway management needs by integrating gastric access and intubation capability in an anatomically curved single-use device that facilitates rapid establishment of a safe airway.
• Rapid placement
The soft rounded curve of the AuraGain, pre-formed to follow the anatomy of the human airway, ensures rapid placement and guarantees long-term performance. The thin and soft cuff of the AuraGain is designed to deliver high seal pressures.
• Gastric control
The integrated gastric access channel is designed with a low friction inner surface to facilitate easy placement of a gastric tube, to enable active and passive management of gastric content and prevent gastric insufflation.
• Integrated intubation capability
It provides the added safety feature of intubation capability. This means that in case of an unexpected difficult airway, or a "Cannot Intubate - Cannot mask Ventilate" (CI-CV) situation, where the endgame is to intubate the patient, AuraGain can be used as conduit for direct endotracheal intubation assisted by a flexible scope.
• All-round versatility
Rapid placement, high seal pressure, gastric access and intubation capability make the AuraGain the obvious and safe choice for every procedure where a laryngeal mask is indicated.
Ambu® AURAGAIN™ VENTILATION, INTUBATION, GASTRIC ACCESS
Soft bite absorption area with helpful markings and accessory size information.
Navigation marks for guiding flexible endoscopes.
Direct endotracheal intubation using a flexible scope and standard ET-tubes. | SILICONE REUSABLE LARYNGEAL AIRWAY MASK
1. Optimal anatomical design ensure convenient and safe insertion. Universal 15 mm connector (ISO).
2. See-through fl exible airway tube, clear guideline for easy insertion.
3. Tiny protruding bumps minimize the vomiting substance fl owing from exophagus and into the lung.
4. Seamless cuff formation offers maximum comfort.
5. Strengthened oval tip prevents possible bending during insertion.
6. Thin walled pilot balloon facilitates the sensing of the infl ation tube.
Each laryngeal airway mask is individually serialized for identification and traceability purposes.
AUTOCLAVABLE UP TO 40 TIME. | SILICONE REUSABLE LARYNGEAL AIRWAY MASK
1. Optimal anatomical design ensure convenient and safe insertion. Universal 15 mm connector (ISO).
2. See-through fl exible airway tube, clear guideline for easy insertion.
3. Tiny protruding bumps minimize the vomiting substance fl owing from exophagus and into the lung.
4. Seamless cuff formation offers maximum comfort.
5. Strengthened oval tip prevents possible bending during insertion.
6. Thin walled pilot balloon facilitates the sensing of the infl ation tube.
Each laryngeal airway mask is individually serialized for identification and traceability purposes.
AUTOCLAVABLE UP TO 40 TIME. | AMBU® AURAGAIN™ DISPOSABLE LARYNGEAL MASKS
• Laryngeal Mask N 2.5
• Patient weight: 20-30 kg
• Max mask ET-Tubes Max (Ø of endotracheal tube): 5.5 mm
• Gastric-Tube max (FR): 10 FR
• Maximum cuff inflation volume: 14 ml
The AuraGain satisfies 3 fundamental airway management needs by integrating gastric access and intubation capability in an anatomically curved single-use device that facilitates rapid establishment of a safe airway.
• Rapid placement
The soft rounded curve of the AuraGain, pre-formed to follow the anatomy of the human airway, ensures rapid placement and guarantees long-term performance. The thin and soft cuff of the AuraGain is designed to deliver high seal pressures.
• Gastric control
The integrated gastric access channel is designed with a low friction inner surface to facilitate easy placement of a gastric tube, to enable active and passive management of gastric content and prevent gastric insufflation.
• Integrated intubation capability
It provides the added safety feature of intubation capability. This means that in case of an unexpected difficult airway, or a "Cannot Intubate - Cannot mask Ventilate" (CI-CV) situation, where the endgame is to intubate the patient, AuraGain can be used as conduit for direct endotracheal intubation assisted by a flexible scope.
• All-round versatility
Rapid placement, high seal pressure, gastric access and intubation capability make the AuraGain the obvious and safe choice for every procedure where a laryngeal mask is indicated.
Ambu® AURAGAIN™ VENTILATION, INTUBATION, GASTRIC ACCESS
Soft bite absorption area with helpful markings and accessory size information.
Navigation marks for guiding flexible endoscopes.
Direct endotracheal intubation using a flexible scope and standard ET-tubes. | SILICONE REUSABLE LARYNGEAL AIRWAY MASK
1. Optimal anatomical design ensure convenient and safe insertion. Universal 15 mm connector (ISO).
2. See-through fl exible airway tube, clear guideline for easy insertion.
3. Tiny protruding bumps minimize the vomiting substance fl owing from exophagus and into the lung.
4. Seamless cuff formation offers maximum comfort.
5. Strengthened oval tip prevents possible bending during insertion.
6. Thin walled pilot balloon facilitates the sensing of the infl ation tube.
Each laryngeal airway mask is individually serialized for identification and traceability purposes.
AUTOCLAVABLE UP TO 40 TIME. |
Additional information |
Weight |
0.3 kg |
Dimensions |
26 × 19 × 12 cm |
Technical Specification |
Maximum intra-cuff pressure: 60 cm H2O Airway connector: 15 mm ISO 5356-1 Tube/cuff material: PVC (latex and phthalates free) Complete range for neonatal (AuraGain only), pediatric and adult patients Packaged sterile and ready for use Colour coded pouch with directions for use
|
Unit |
1 pc.
|
|
Weight |
0.067 kg |
Dimensions |
27 × 13 × 5 cm |
Technical Specification |
Maximum intra-cuff pressure: 60 cm H2O Airway connector: 15 mm ISO 5356-1 Tube/cuff material: PVC (latex and phthalates free) Complete range for neonatal (AuraGain only), pediatric and adult patients Packaged sterile and ready for use Colour coded pouch with directions for use
|
Unit |
1 pc.
|
|
Weight |
0.4 kg |
Dimensions |
34 × 24 × 8 cm |
Technical Specification |
• Size: 4 • Patient range: adult • Weight range: 50-70 Kg • Cuff volume (ml. of air): 30 ml
|
Unit |
1 pc.
|
|
Weight |
0.4 kg |
Dimensions |
36 × 24 × 6 cm |
Technical Specification |
• Size: 3 • Patient range: boy • Weight range: 30-50 Kg • Cuff volume (ml. of air): 20 ml
|
Unit |
1 pc.
|
|
Weight |
0.06 kg |
Dimensions |
23.5 × 13 × 4 cm |
Technical Specification |
Maximum intra-cuff pressure: 60 cm H2O Airway connector: 15 mm ISO 5356-1 Tube/cuff material: PVC (latex and phthalates free) Complete range for neonatal (AuraGain only), pediatric and adult patients Packaged sterile and ready for use Colour coded pouch with directions for use
|
Unit |
1 pc.
|
|
Weight |
0.4 kg |
Dimensions |
36 × 24 × 6 cm |
Technical Specification |
• Size: 2.5 • Patient range: child • Weight range: 20-30 Kg • Cuff volume (ml. of air): 14 ml
|
Unit |
1 pc.
|
|