AMBU® AURAONCE™ DISPOSABLE LARYNGEAL MASKS

• Laryngeal Mask N 2.5
• Colour: pink
• Patient weight: 20-30 kg
• Maximum cuff inflation volume: 14 ml

AuraOnce has a special curve that carefully replicates natural human anatomy.
Molded directly into the tube, the unique shape makes correct insertion easy without abrading the upper airway.
AuraOnce’s curve also ensures that the patient’s head remains in a natural supine position when the mask is in use without extra stress on the upper jaw. Moreover, Auraonce is specially designed to give the airway tube the flexibility needed to adapt to individual anatomical variances and wide range of
head positions.

AuraOnce has a D-shaped airway tube to give a firm and ergonomical grip during insertion. In short, positioning is fast and accurate, with least possible internal pressure.

The airway tube is flexible at the cuff and rigid at the connector for easy, atraumatic insertion and removal.
Cuff and airway tube moulded as single unit with built-in, anatomically correct curve.
Smooth sides without ridges or fins that can scratch delicate tissue.
Reinforced tip will not bend during insertion so positioning is always correct.
Ultra thin pilot balloon with universal check valve provides precise tactile indication of degree of inflation.
Reinforced tip will not bend during insertion so positioning is always correct.
Universal 15 mm connector (ISO).


Product PDF Download

SKU: 34407 Category: Tag:

Quick Comparison

AURAONCE DISPOSABLE LARYNGEAL MASK N 2.5 removeAMBU AURA-i DISPOSABLE LARYNGEAL MASK N 2 removeAMBU AURA-i DISPOSABLE LARYNGEAL MASK N 4 removeLARYNGEAL MASK 5 without holes - adult large removeAMBU AURA-i DISPOSABLE LARYNGEAL MASK N 2.5 removeAMBU AURAGAIN DISPOSABLE LARYNGEAL MASK N 5 remove
NameAURAONCE DISPOSABLE LARYNGEAL MASK N 2.5 removeAMBU AURA-i DISPOSABLE LARYNGEAL MASK N 2 removeAMBU AURA-i DISPOSABLE LARYNGEAL MASK N 4 removeLARYNGEAL MASK 5 without holes - adult large removeAMBU AURA-i DISPOSABLE LARYNGEAL MASK N 2.5 removeAMBU AURAGAIN DISPOSABLE LARYNGEAL MASK N 5 remove
Image
SKU344073459334596344293459457606
Rating
PriceOMR 7OMR 8OMR 8OMR 49OMR 8OMR 12
Stock
Availability
Add to cart

Description
ContentAMBU® AURAONCE™ DISPOSABLE LARYNGEAL MASKS • Laryngeal Mask N 2.5 • Colour: pink • Patient weight: 20-30 kg • Maximum cuff inflation volume: 14 ml AuraOnce has a special curve that carefully replicates natural human anatomy. Molded directly into the tube, the unique shape makes correct insertion easy without abrading the upper airway. AuraOnce's curve also ensures that the patient's head remains in a natural supine position when the mask is in use without extra stress on the upper jaw. Moreover, Auraonce is specially designed to give the airway tube the flexibility needed to adapt to individual anatomical variances and wide range of head positions. AuraOnce has a D-shaped airway tube to give a firm and ergonomical grip during insertion. In short, positioning is fast and accurate, with least possible internal pressure. The airway tube is flexible at the cuff and rigid at the connector for easy, atraumatic insertion and removal. Cuff and airway tube moulded as single unit with built-in, anatomically correct curve. Smooth sides without ridges or fins that can scratch delicate tissue. Reinforced tip will not bend during insertion so positioning is always correct. Ultra thin pilot balloon with universal check valve provides precise tactile indication of degree of inflation. Reinforced tip will not bend during insertion so positioning is always correct. Universal 15 mm connector (ISO).
Product PDF Download
AMBU® AURA-i™ DISPOSABLE LARYNGEAL MASKS • Laryngeal Mask N 2 • Colour: pink • Patient weight: 10-20 kg • Maximum cuff inflation volume: 10 ml • Max mask ET-Tubes Max (Ø of endotracheal tube): 5.0 mm The soft rounded curve of the Aura-i pre-formed to follow the anatomy of the human airway, ensures fast and easy placement and guarantees long-term performance. Aura-i is the preferred everyday routine device for establishing an airway where an ET-tube is deemed unnecessary. At the same time it holds a place on the difficult airway cart. In case of a “Cannot Intubate - Cannot mask Ventilate” (CI-CV) situation, where the purpose is to intubate the patient, Aura-i can be used as conduit for direct endotracheal intubation assisted by a flexible scope. The airway tube is designed to allow easy passage of an appropriately sized ET-tube. The recommended ET-tube size is indicated on the connector block of the mask. Ambu® AURA-i™ VENTILATION & INTUBATION Built-in, anatomically correct curve for fast and easy insertion. Navigation marks to guide flexible scope. Reinforced tip resists folding over during insertion and plugs the upper esophageal sphincter. Smooth sides without ridges or fins that can scratch delicate tissue. Ultra thin pilot balloon identifies mask size and provides precise tactile indication of degree of inflation. Direct endotracheal intubation using a flexible scope and standard ET-tubes. Intubation capability using standard ET-tubes. Universal 15 mm connector (ISO).
Product PDF Download
AAMBU® AURA-i™ DISPOSABLE LARYNGEAL MASKS • Laryngeal Mask N 4 • Colour: orange • Patient weight: 50-70 kg • Maximum cuff inflation volume: 30 ml • Max mask ET-Tubes Max (Ø of endotracheal tube): 7.5 mm The soft rounded curve of the Aura-i pre-formed to follow the anatomy of the human airway, ensures fast and easy placement and guarantees long-term performance. Aura-i is the preferred everyday routine device for establishing an airway where an ET-tube is deemed unnecessary. At the same time it holds a place on the difficult airway cart. In case of a “Cannot Intubate - Cannot mask Ventilate” (CI-CV) situation, where the purpose is to intubate the patient, Aura-i can be used as conduit for direct endotracheal intubation assisted by a flexible scope. The airway tube is designed to allow easy passage of an appropriately sized ET-tube. The recommended ET-tube size is indicated on the connector block of the mask. Ambu® AURA-i™ VENTILATION & INTUBATION Built-in, anatomically correct curve for fast and easy insertion. Navigation marks to guide flexible scope. Reinforced tip resists folding over during insertion and plugs the upper esophageal sphincter. Smooth sides without ridges or fins that can scratch delicate tissue. Ultra thin pilot balloon identifies mask size and provides precise tactile indication of degree of inflation. Direct endotracheal intubation using a flexible scope and standard ET-tubes. Intubation capability using standard ET-tubes. Universal 15 mm connector (ISO).
Product PDF Download
SILICONE REUSABLE LARYNGEAL AIRWAY MASK 1. Optimal anatomical design ensure convenient and safe insertion. Universal 15 mm connector (ISO). 2. See-through fl exible airway tube, clear guideline for easy insertion. 3. Tiny protruding bumps minimize the vomiting substance fl owing from exophagus and into the lung. 4. Seamless cuff formation offers maximum comfort. 5. Strengthened oval tip prevents possible bending during insertion. 6. Thin walled pilot balloon facilitates the sensing of the infl ation tube. Each laryngeal airway mask is individually serialized for identification and traceability purposes. AUTOCLAVABLE UP TO 40 TIME.
Product PDF Download
AMBU® AURA-i™ DISPOSABLE LARYNGEAL MASKS • Laryngeal Mask N 2.5 • Colour: pink • Patient weight: 20-30 kg • Maximum cuff inflation volume: 14 ml • Max mask ET-Tubes Max (Ø of endotracheal tube): 5.5 mm The soft rounded curve of the Aura-i pre-formed to follow the anatomy of the human airway, ensures fast and easy placement and guarantees long-term performance. Aura-i is the preferred everyday routine device for establishing an airway where an ET-tube is deemed unnecessary. At the same time it holds a place on the difficult airway cart. In case of a “Cannot Intubate - Cannot mask Ventilate” (CI-CV) situation, where the purpose is to intubate the patient, Aura-i can be used as conduit for direct endotracheal intubation assisted by a flexible scope. The airway tube is designed to allow easy passage of an appropriately sized ET-tube. The recommended ET-tube size is indicated on the connector block of the mask. Ambu® AURA-i™ VENTILATION & INTUBATION Built-in, anatomically correct curve for fast and easy insertion. Navigation marks to guide flexible scope. Reinforced tip resists folding over during insertion and plugs the upper esophageal sphincter. Smooth sides without ridges or fins that can scratch delicate tissue. Ultra thin pilot balloon identifies mask size and provides precise tactile indication of degree of inflation. Direct endotracheal intubation using a flexible scope and standard ET-tubes. Intubation capability using standard ET-tubes. Universal 15 mm connector (ISO).
Product PDF Download
AMBU® AURAGAIN™ DISPOSABLE LARYNGEAL MASKS • Laryngeal Mask N 5 • Patient weight: 70-100 kg • Max mask ET-Tubes Max (Ø of endotracheal tube): 8.0 mm • Gastric-Tube max (FR): 16 FR • Maximum cuff inflation volume: 40 ml The AuraGain satisfies 3 fundamental airway management needs by integrating gastric access and intubation capability in an anatomically curved single-use device that facilitates rapid establishment of a safe airway. • Rapid placement The soft rounded curve of the AuraGain, pre-formed to follow the anatomy of the human airway, ensures rapid placement and guarantees long-term performance. The thin and soft cuff of the AuraGain is designed to deliver high seal pressures. • Gastric control The integrated gastric access channel is designed with a low friction inner surface to facilitate easy placement of a gastric tube, to enable active and passive management of gastric content and prevent gastric insufflation. • Integrated intubation capability It provides the added safety feature of intubation capability. This means that in case of an unexpected difficult airway, or a "Cannot Intubate - Cannot mask Ventilate" (CI-CV) situation, where the endgame is to intubate the patient, AuraGain can be used as conduit for direct endotracheal intubation assisted by a flexible scope. • All-round versatility Rapid placement, high seal pressure, gastric access and intubation capability make the AuraGain the obvious and safe choice for every procedure where a laryngeal mask is indicated. Ambu® AURAGAIN™ VENTILATION, INTUBATION, GASTRIC ACCESS Soft bite absorption area with helpful markings and accessory size information. Navigation marks for guiding flexible endoscopes. Direct endotracheal intubation using a flexible scope and standard ET-tubes.
Weight0.05 kg0.2 kg0.2 kg0.1 kg0.2 kg0.114 kg
Dimensions27 × 19 × 4 cm13 × 18.5 × 4 cm13 × 18.5 × 4 cm3 × 33 × 22 cm13 × 18.5 × 4 cm27 × 19 × 7 cm
Additional information
Weight 0.05 kg
Dimensions 27 × 19 × 4 cm
Technical Specification

Maximum intra-cuff pressure: 60 cm H2O Airway connector: 15 mm ISO 5356-1 Tube/cuff material: PVC (latex and phthalates free) Complete range for neonatal (AuraGain only), pediatric and adult patients Packaged sterile and ready for use Colour coded pouch with directions for use

Unit

1 pc.

Weight 0.2 kg
Dimensions 13 × 18.5 × 4 cm
Technical Specification

Maximum intra-cuff pressure: 60 cm H2O Airway connector: 15 mm ISO 5356-1 Tube/cuff material: PVC (latex and phthalates free) Complete range for neonatal (AuraGain only), pediatric and adult patients Packaged sterile and ready for use Colour coded pouch with directions for use

Unit

1 pc.

Weight 0.2 kg
Dimensions 13 × 18.5 × 4 cm
Technical Specification

Maximum intra-cuff pressure: 60 cm H2O Airway connector: 15 mm ISO 5356-1 Tube/cuff material: PVC (latex and phthalates free) Complete range for neonatal (AuraGain only), pediatric and adult patients Packaged sterile and ready for use Colour coded pouch with directions for use

Unit

1 pc.

Weight 0.1 kg
Dimensions 3 × 33 × 22 cm
Technical Specification

• Size: 5 • Patient range: adult • Weight range: > 70 Kg • Cuff volume (ml. of air): 40 ml

Unit

1 pc.

Weight 0.2 kg
Dimensions 13 × 18.5 × 4 cm
Technical Specification

Maximum intra-cuff pressure: 60 cm H2O Airway connector: 15 mm ISO 5356-1 Tube/cuff material: PVC (latex and phthalates free) Complete range for neonatal (AuraGain only), pediatric and adult patients Packaged sterile and ready for use Colour coded pouch with directions for use

Unit

1 pc.

Weight 0.114 kg
Dimensions 27 × 19 × 7 cm
Technical Specification

Maximum intra-cuff pressure: 60 cm H2O Airway connector: 15 mm ISO 5356-1 Tube/cuff material: PVC (latex and phthalates free) Complete range for neonatal (AuraGain only), pediatric and adult patients Packaged sterile and ready for use Colour coded pouch with directions for use

Unit

1 pc.

shipping Set Your Delivery Location
en_USEnglish
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare